Andesite contract crushing: Variable feed gradation — solution & design basis
Crusher power draw swings sharply with each loader cycle — a 110 t/h design basis, configuration and acceptance checks…
Read the solutionGood cubicity after a VSI shaping pass; consistent choke feed is needed to hold the flakiness index within the asphalt specification.
43 engineering articles that start from the properties of andesite rather than from a catalogue capacity figure.
How is andesite processed? Good cubicity after a VSI shaping pass; consistent choke feed is needed to hold the flakiness index within the asphalt specification. Indicative properties are 120–240 MPa compressive strength, medium–high abrasiveness, low moisture sensitivity and 1.44 t/m³ loose bulk density. A typical train is jaw → cone → VSI → screen, producing asphalt aggregate, 0–5, 5–16 mm. All values are nominal selection figures.
| Parameter | Nominal value / typical target |
|---|---|
| Raw material | Andesite |
| Compressive strength | 120–240 MPa |
| Abrasion | medium–high |
| Moisture sensitivity | low |
| Loose bulk density | 1.44 t/m³ |
| Typical circuit | jaw → cone → VSI → screen |
| Saleable fractions | asphalt aggregate, 0–5, 5–16 mm |
Crusher power draw swings sharply with each loader cycle — a 110 t/h design basis, configuration and acceptance checks…
Read the solution
The plant cannot hold a steady feed during its first weeks — a 150 t/h design basis, configuration and acceptance chec…
Read the solution
The product sieve curve drifts outside its envelope between shifts — a 120 t/h design basis, configuration and accepta…
Read the solution
The investment case compares purchase prices instead of lifetime cost — a 160 t/h design basis, configuration and acce…
Read the solutionGrouped by plant scenario and engineering problem. Each page states its assumptions with units and separates nominal figures from guaranteed performance.
Direct answers to the questions buyers ask most often.
A typical configuration is jaw → cone → VSI → screen. Good cubicity after a VSI shaping pass; consistent choke feed is needed to hold the flakiness index within the asphalt specification. The final equipment list depends on feed gradation, moisture, saleable fractions and local power and space limits.
Indicative compressive strength 120–240 MPa, abrasion medium–high, moisture sensitivity low and loose bulk density around 1.44 t/m³. These are nominal ranges for selection, not test certificates for a specific quarry.
Common saleable fractions are asphalt aggregate, 0–5, 5–16 mm. The grading standard and sampling method must be written into the acceptance test, because aperture series differ between ASTM, EN and ISO.
No. They are engineering configurations and design studies published for equipment selection. For documented deliveries see the project reference library; ask for a written flow sheet before ordering.
Our engineers will return a process flow, equipment list and budget quotation within 24 hours — at no cost and with no obligation.