Coal greenfield plant: CAPEX justification — solution & design basis
The investment case compares purchase prices instead of lifetime cost — a 250 t/h design basis, configuration and acce…
Read the solutionLow bulk density flips the usual sizing logic: volume, dust and explosion protection dominate over crusher power.
29 engineering articles that start from the properties of coal rather than from a catalogue capacity figure.
How is coal processed? Low bulk density flips the usual sizing logic: volume, dust and explosion protection dominate over crusher power. Indicative properties are 10–50 MPa compressive strength, very low abrasiveness, variable moisture sensitivity and 0.85 t/m³ loose bulk density. A typical train is sizer / impact → screen, producing −50 mm and washed size fractions. All values are nominal selection figures.
| Parameter | Nominal value / typical target |
|---|---|
| Raw material | Coal |
| Compressive strength | 10–50 MPa |
| Abrasion | very low |
| Moisture sensitivity | variable |
| Loose bulk density | 0.85 t/m³ |
| Typical circuit | sizer / impact → screen |
| Saleable fractions | −50 mm and washed size fractions |
The investment case compares purchase prices instead of lifetime cost — a 250 t/h design basis, configuration and acce…
Read the solution
Crusher power draw swings sharply with each loader cycle — a 55 t/h design basis, configuration and acceptance checks.…
Read the solution
The investment case compares purchase prices instead of lifetime cost — a 100 t/h design basis, configuration and acce…
Read the solution
The investment case compares purchase prices instead of lifetime cost — a 290 t/h design basis, configuration and acce…
Read the solutionGrouped by plant scenario and engineering problem. Each page states its assumptions with units and separates nominal figures from guaranteed performance.
Direct answers to the questions buyers ask most often.
A typical configuration is sizer / impact → screen. Low bulk density flips the usual sizing logic: volume, dust and explosion protection dominate over crusher power. The final equipment list depends on feed gradation, moisture, saleable fractions and local power and space limits.
Indicative compressive strength 10–50 MPa, abrasion very low, moisture sensitivity variable and loose bulk density around 0.85 t/m³. These are nominal ranges for selection, not test certificates for a specific quarry.
Common saleable fractions are −50 mm and washed size fractions. The grading standard and sampling method must be written into the acceptance test, because aperture series differ between ASTM, EN and ISO.
No. They are engineering configurations and design studies published for equipment selection. For documented deliveries see the project reference library; ask for a written flow sheet before ordering.
Our engineers will return a process flow, equipment list and budget quotation within 24 hours — at no cost and with no obligation.