● Crushing & grinding equipment · Since 2004
Equipment
Wheel Type Mobile CrushersTracked Crushing PlantsCone CrusherJaw CrusherImpact CrusherGrinding MillsModular Crushing PlantSupporting EquipmentsSand Making & Washing
Solutions
All solutionsEngineering solutions (700)Circuit designGrinding & mineralsProjectsMarkets
Company
About HAMACResourcesIndustry glossaryBlogFAQWear partsContact
Grinding

LUM Ultrafine Vertical Mill for Coal flue-gas desulfurization: Iron contamination and whiteness loss

Brightness falls and dark specks appear in the finished filler — a 10 t/h design basis for LUM Ultrafine Vertical Mill, configuration and acceptance checks.

LUM Ultrafine Vertical Mill for Coal flue-gas desulfurization with iron contamination and whiteness loss is normally resolved by checking the grinding circuit against the target 75–200 D97 first: fit a magnetic separator and metal detector before the mill. For a 10 t/h design point on coal, HAMAC would review crusher → dryer → vertical / ball mill, then confirm the classifier setting with a written acceptance test. Two plants with the same nominal t/h can have very different operating costs.

10 t/hindicative powder output
D97 75–200 µmtarget fineness band
1–2Mohs hardness
140 kWorder-of-magnitude installed power
Key takeaways
  1. Coal is very soft (Mohs 1–2) with variable moisture sensitivity; Explosion protection and drying dominate; fineness sets combustion efficiency.
  2. For flue-gas desulfurization the priority is reactivity / fineness, constrained by reaction activity tied to surface area.
  3. LUM Ultrafine Vertical Mill covers 3–18 t/h at 400–2500 mesh (D97 3–20 µm).
  4. Iron contamination and whiteness loss typically appears as: brightness falls and dark specks appear in the finished filler.
  5. First corrective action: fit a magnetic separator and metal detector before the mill.
  6. All values are nominal; confirm them in a written proposal with a defined test method.

Design basis for LUM Ultrafine Vertical Mill grinding coal

The design basis starts with the powder, not the mill. Coal is a very soft mineral at Mohs 1–2 with variable moisture sensitivity and specific gravity about 1.3. For a flue-gas desulfurization the saleable target is pulverised coal, 70–90% <200 mesh at D97 75–200 µm. Explosion protection and drying dominate; fineness sets combustion efficiency. Operator notes from the first month are often the best diagnostic data.

A LUM Ultrafine Vertical Mill is a sensible starting point for this duty: 3–18 t/h capacity, 400–2500 mesh (D97 3–20 µm) fineness range, premium ultrafine powder with low iron contamination. For this combination HAMAC works from an indicative design point of 10 t/h of saleable powder, with a maximum feed size near 35 mm and a target D97 of 75–200. Fineness is a distribution, not a single mesh number.

LUM Ultrafine Vertical Mill — design basis for Coal (nominal values)
ParameterIndicative value / method
Raw materialCoal · Mohs 1–2 · very soft · SG 1.3
Design throughput10 t/h saleable powder (8–40 t/h scenario band)
Target finenessD97 75–200 µm
Maximum feed size~35 mm
Mill typeLUM Ultrafine Vertical Mill
Suggested linecrusher → dryer → vertical / ball mill
Coal flue-gas desulfurization — Design basis for LUM Ultrafine Vertical Mill grinding coal — HAMAC grinding mill
Coal flue-gas desulfurization — Design basis for LUM Ultrafine Vertical Mill grinding coal — HAMAC grinding mill reference.

Why iron contamination and whiteness loss appears in this grinding circuit

Brightness falls and dark specks appear in the finished filler. In a LUM Ultrafine Vertical Mill circuit on coal this is usually a system symptom across the mill, classifier and collector rather than a single machine fault. Two plants with the same nominal t/h can have very different operating costs.

  • tramp iron passes the upstream magnet
  • worn liners and grinding elements add metallic fines
  • mild-steel ducting or a worn classifier rotor sheds scale

Record the setting before adjusting it, or the baseline is lost. Before changing a mill setting, check these in order: 1) measure brightness on every finished batch; 2) test the magnet with a sample piece weekly; 3) inspect liners and rotor blades at each planned stop. HAMAC states nominal values alongside the conditions they were measured under.

Recommended grinding configuration

For coal at 10 t/h the working line is crusher → dryer → vertical / ball mill. The LUM Ultrafine Vertical Mill sits at the centre; a dynamic air classifier sets the cut and a pulse-jet bag filter holds the system under negative pressure so the finished powder stays clean. Operator notes from the first month are often the best diagnostic data.

Indicative stage configuration
ParameterIndicative value / method
FeedingWeigh / belt feeder, VFD control, ~12 t/h design margin
MillingLUM Ultrafine Vertical Mill, 3–18 t/h, 400–2500 mesh (D97 3–20 µm)
ClassificationDynamic air classifier, rotor speed tuned to target D97 75–200
CollectionPulse-jet bag filter, negative pressure, ~18 m³/min air volume
Conveying / airCentrifugal fan and ducting sized for 18 m³/min total air
ControlInterlocked start-up, load-based feed trim, ~140 kW connected load

The corrective actions for iron contamination and whiteness loss are applied on top of this base circuit: fit a magnetic separator and metal detector before the mill; select wear materials against the required brightness specification; inspect and line the conveying path for exposed steel.

Coal flue-gas desulfurization — Recommended grinding configuration — HAMAC grinding mill
Coal flue-gas desulfurization — Recommended grinding configuration — HAMAC grinding mill reference.

Operating settings and acceptance checks

Settings must be recorded at commissioning and re-checked after any liner, rotor or media change. For this circuit the starting point is a classifier rotor speed that holds D97 75–200, a circulating load around 35% and a collection efficiency above 99%. Record the setting before adjusting it, or the baseline is lost.

  • Measure brightness on every finished batch
  • Test the magnet with a sample piece weekly
  • Inspect liners and rotor blades at each planned stop
Acceptance checks to write into the contract
ParameterIndicative value / method
FinenessLaser diffraction / sieve, target D97 75–200, agreed standard
CapacityWeighed saleable powder per shift, 10 t/h nominal
MoistureFeed and product moisture each shift
PowerMain drive current at steady feed, ~140 kW connected load
PurityBrightness / Fe content batch check for white fillers

HAMAC states nominal values alongside the conditions they were measured under. All figures published on this site are nominal engineering values; actual performance depends on feed gradation, moisture, mill setting and classifier efficiency.

Cost, risk and what to confirm in writing

Compare this grinding plant as cost per tonne of saleable powder, not purchase price. Energy, wear parts, media and downtime dominate the operating cost for coal, while reactivity / fineness determines how much lost production actually costs. Two plants with the same nominal t/h can have very different operating costs.

  • Ask every supplier for the same flow sheet and mass balance, including the 35% return / circulating load.
  • State the Incoterm, named port, civils scope, erection scope and a two-year spares list in the quotation.
  • Model annual output as 10 t/h × scheduled hours × realistic utilisation (often 75–90%), not as nameplate × 8,760 hours.
  • Agree the fineness test method (laser diffraction vs. sieve), sampling point and acceptance test before the order is placed.

Operator notes from the first month are often the best diagnostic data. HAMAC states nominal values alongside the conditions they were measured under. Send your material, feed size, target fineness and capacity to HAMAC Machinery for a comparable configuration and budget.

Coal flue-gas desulfurization — Cost, risk and what to confirm in writing — HAMAC grinding mill
Coal flue-gas desulfurization — Cost, risk and what to confirm in writing — HAMAC grinding mill reference.
FAQ

Coal flue-gas desulfurization — questions answered

Direct answers to the questions buyers ask most often.

What causes iron contamination and whiteness loss in a LUM Ultrafine Vertical Mill circuit on coal?

Brightness falls and dark specks appear in the finished filler. The usual causes are tramp iron passes the upstream magnet; worn liners and grinding elements add metallic fines; mild-steel ducting or a worn classifier rotor sheds scale. fit a magnetic separator and metal detector before the mill.

Which mill suits coal at 8–40 t/h?

A typical configuration is crusher → dryer → vertical / ball mill. LUM Ultrafine Vertical Mill covers 3–18 t/h at 400–2500 mesh (D97 3–20 µm). Explosion protection and drying dominate; fineness sets combustion efficiency. The final list depends on feed size, moisture, target D97 and local power limits.

What should be confirmed before ordering a 10 t/h grinding plant?

A written flow sheet and mass balance, the fineness test method and target D97, mill and classifier size, installed power and starting method, the Incoterm and named port, a spares list, and an acceptance test with a defined sampling method. All published figures are nominal.

Request a quotation

Tell us what you need

A short message is enough. A HAMAC engineer replies with a flow sheet and budget within 24 hours.

Ask an engineer about this configuration

Two fields are enough. An engineer replies with a flow sheet and budget within 24 hours.

Not sure what to write? Tap what fits. optional · one tap each
Material
Target capacity
We only use your details to answer this enquiry. Privacy Policy
✆

WhatsApp / Mobile

+86-151-3623-6223
☎
⌖

Factory & headquarters

No. 57 Kexue Avenue, National Hi-Tech Industrial Development Zone, Zhengzhou, Henan, China

⏱

Response time

Technical reply within 24 hours, Monday to Saturday.

Have the feed data for your own site?

Send material, maximum feed size, target t/h and required fractions — a HAMAC engineer will return a written flow sheet and budget.

WhatsApp Get a quote Call