Design basis for LUM Ultrafine Vertical Mill grinding marble
The design basis starts with the powder, not the mill. Marble is a soft mineral at Mohs 3 with low moisture sensitivity and specific gravity about 2.7. For a flue-gas desulfurization the saleable target is ground calcium carbonate, chips at D97 10–120 µm. Valued for whiteness, so iron contamination and tramp-metal protection matter more than reduction ratio. Operator notes from the first month are often the best diagnostic data.
A LUM Ultrafine Vertical Mill is a sensible starting point for this duty: 3–18 t/h capacity, 400–2500 mesh (D97 3–20 µm) fineness range, premium ultrafine powder with low iron contamination. For this combination HAMAC works from an indicative design point of 10 t/h of saleable powder, with a maximum feed size near 25 mm and a target D97 of 10–120. Fineness is a distribution, not a single mesh number.
| Parameter | Indicative value / method |
|---|---|
| Raw material | Marble · Mohs 3 · soft · SG 2.7 |
| Design throughput | 10 t/h saleable powder (8–40 t/h scenario band) |
| Target fineness | D97 10–120 µm |
| Maximum feed size | ~25 mm |
| Mill type | LUM Ultrafine Vertical Mill |
| Suggested line | jaw → impact → screen → grinding / classifier |

Why unstable powder fineness appears in this grinding circuit
D97 drifts even though the mill settings have not changed. In a LUM Ultrafine Vertical Mill circuit on marble this is usually a system symptom across the mill, classifier and collector rather than a single machine fault. Most of these problems are diagnosed at the screen, not at the crusher.
- classifier rotor speed and system air flow are tuned independently
- duct leakage changes the real air volume
- feed moisture or top size varies between batches
Measurements are only comparable when the sieve standard is the same. Before changing a mill setting, check these in order: 1) sample D50 and D97 every hour for a full shift; 2) measure airflow at the mill outlet; 3) check bag-filter differential pressure. A signed settings log at handover protects both parties later.
Recommended grinding configuration
For marble at 10 t/h the working line is jaw → impact → screen → grinding / classifier. The LUM Ultrafine Vertical Mill sits at the centre; a dynamic air classifier sets the cut and a pulse-jet bag filter holds the system under negative pressure so the finished powder stays clean. Operator notes from the first month are often the best diagnostic data.
| Parameter | Indicative value / method |
|---|---|
| Feeding | Weigh / belt feeder, VFD control, ~12 t/h design margin |
| Milling | LUM Ultrafine Vertical Mill, 3–18 t/h, 400–2500 mesh (D97 3–20 µm) |
| Classification | Dynamic air classifier, rotor speed tuned to target D97 10–120 |
| Collection | Pulse-jet bag filter, negative pressure, ~12 m³/min air volume |
| Conveying / air | Centrifugal fan and ducting sized for 12 m³/min total air |
| Control | Interlocked start-up, load-based feed trim, ~140 kW connected load |
The corrective actions for unstable powder fineness are applied on top of this base circuit: tune classifier speed and fan damper as one control loop; seal the ducting and verify air volume at the collector; stabilise feed size and moisture before the mill inlet.

Operating settings and acceptance checks
Settings must be recorded at commissioning and re-checked after any liner, rotor or media change. For this circuit the starting point is a classifier rotor speed that holds D97 10–120, a circulating load around 35% and a collection efficiency above 99%. Measurements are only comparable when the sieve standard is the same.
- Sample D50 and D97 every hour for a full shift
- Measure airflow at the mill outlet
- Check bag-filter differential pressure
| Parameter | Indicative value / method |
|---|---|
| Fineness | Laser diffraction / sieve, target D97 10–120, agreed standard |
| Capacity | Weighed saleable powder per shift, 10 t/h nominal |
| Moisture | Feed and product moisture each shift |
| Power | Main drive current at steady feed, ~140 kW connected load |
| Purity | Brightness / Fe content batch check for white fillers |
A signed settings log at handover protects both parties later. All figures published on this site are nominal engineering values; actual performance depends on feed gradation, moisture, mill setting and classifier efficiency.
Cost, risk and what to confirm in writing
Compare this grinding plant as cost per tonne of saleable powder, not purchase price. Energy, wear parts, media and downtime dominate the operating cost for marble, while reactivity / fineness determines how much lost production actually costs. Most of these problems are diagnosed at the screen, not at the crusher.
- Ask every supplier for the same flow sheet and mass balance, including the 35% return / circulating load.
- State the Incoterm, named port, civils scope, erection scope and a two-year spares list in the quotation.
- Model annual output as 10 t/h × scheduled hours × realistic utilisation (often 75–90%), not as nameplate × 8,760 hours.
- Agree the fineness test method (laser diffraction vs. sieve), sampling point and acceptance test before the order is placed.
Operator notes from the first month are often the best diagnostic data. A signed settings log at handover protects both parties later. Send your material, feed size, target fineness and capacity to HAMAC Machinery for a comparable configuration and budget.